A complete walkthrough: from an empty configuration to two LED surfaces rendered by one Viz Engine,
verified with the test room — and then extended to a second engine with wall groups.

The studio in this example:

  • an LED back wall, 8 m wide and 3.5 m high, standing 5 m behind the studio origin;

  • an LED floor, 8 m wide and 5 m deep, between the back wall and the origin;

  • both driven by one Viz Engine at 192.168.0.10;

  • later, an L-shaped side wall added on a second engine at 192.168.0.20.

image-20260925-084315.png


All values are in centimetres, measured from the studio origin. Where a coordinate sign does not
match your studio, flip it — the 3D view shows immediately which way the wall moved.


Step 1 — Add the videowall service

  1. Open the Topology view.

  2. Right-click in the service area → Add video wall service.

  3. Select the new service and set:

    • IP — 192.168.0.10

    • Port — 3000

    • Command port — 6100

    • Wall Group — 1

  4. Activate the service and make sure the engine is on air.

image-20260925-081652.png

If the engine is not on air, the walls can still be created in the editor — but Create Wall will
report "engine at 10.0.0.31:6100 is not on air" and nothing reaches the engine.


Step 2 — Choose the GFX channel

  1. Open the VW Editor settings: the ... button in the VW Editor header, or Settings →
    VW Editor.

  2. Wall group: 1 — 10.0.0.31. The text beside it should say that the group resolves to one
    engine.

  3. GFX channel: 1.

This is the channel the walls will show. Whatever is played out on GFX1 on that engine is what the
LED surfaces display.

image-20260925-081813.png

Step 3 — Add the back wall

  1. In the VW Editor panel, click the Back Wall button. A wall entry Backwall 1 appears, tinted
    blue (group 1).

  2. Check the 3D view: a flat panel standing 5 m behind the origin, facing the cameras. If it faces
    away, set Rotation to 180; if it stands in front of the origin, use -500 for Position Z.

image-20260925-082059.png

Step 4 — Add the LED floor

The floor is a second Back Wall, laid flat with Floor Mode.

  1. Click the Back Wall button again — Backwall 2 appears, in a second shade of blue.

  2. On its Wall tab, tick Floor Mode (X/Z). The Height field changes its label to
    Depth (Z).

The floor now runs from the studio origin back to the foot of the back wall.

image-20260925-082002.png

Step 5 — Define the Screen mapping

  1. Click on the Screen panel for each wall item.

    1. (Settings → VW Editor → Show advanced actions)

  2. Adjust it for a 50% - 50% split in the engine.

    1. Backwall1:

      1. Position X = 0.00 / Y = 0.00

      2. Dimension W = 50.00 / H = 100.00

    2. Backwall2:

        1. Position X = 50.00 / Y = 0.00

        2. Dimension W = 50.00 / H = 100.00

Activate the NDI Crop option for mapping to be applied on the NDI output as well

image-20260925-083236.png

Step 5 — Create the walls on the engine

  1. Back in the settings, check that Wall group is still 1 — 10.0.0.31.

  2. Press Create Wall.

Studio Manager replaces the scene on the engine, builds both walls in it and then reads the scene
tree back. The status line should read something like:

Group 1: 2 walls confirmed on 10.0.0.31:6100.

If it does not, see Troubleshooting.

image-20260925-082608.png

Create Wall replaces the whole scene on that engine. Anything built in it by hand is lost.


Step 6 — Verify with the test room

The test room is a grid box around the studio origin, shown through the walls. If the walls are
placed correctly, the grid lines continue across them without a jump.

  1. In the Test scene group box, set Room W / H / D to 1200 / 400 / 1200.

  2. Tick Wall grids.

  3. Press Build Room.

On the engine output you should now see the grid room through both LED surfaces, with a coloured
marker grid on each wall showing where Studio Manager thinks that wall is.

image-20260925-082928.png

The Viz Engine output should no show the 2 panels:

image-20260925-083852.png

What to look for:

Observation

Meaning

Grid lines continue across the wall edge

Position and size are right.

Grid appears shifted or scaled on the wall

Check Position and Width/Height of that wall.

Grid tilts on the wall

Check Rotation, or switch to corner mode and enter the measured corners.

Wall shows nothing

The wall containers did not reach the engine, or the GFX channel differs from the one the room was loaded into.

Press Clear Room when you are done. It closes the room on every engine it is on.


Step 7 — Show real content

With the walls built, the engine's GFX1 channel is what the LED surfaces display. Point your playout
or AR scene at GFX1 on that engine.

To see the same content inside Studio Manager, enable the preview per wall:

  1. On the wall's Wall tab, tick Enable NDI.

  2. Pick the engine's NDI output from the drop down (⟳ re-scans).

If one engine output carries the picture for both surfaces side by side, switch on advanced mode
(Settings → VW Editor → Show advanced actions) and use the Screen tab per wall to give each one
its share of the picture, with Crop NDI preview to this area ticked so the Studio Manager preview
matches.

image-20260925-084134.png

Step 8 — Add a second engine with wall groups

Now the studio gets an L-shaped side wall, and it is rendered by its own engine.

  1. Add the second service. Topology → Add video wall service, IP 192.168.0.20, ports 3000 /
    6100, Wall Group 2. Activate it.

  2. Add the wall. In the VW Editor, click the One Corner button. OneCorner 3 appears.

  3. Move it to group 2. In the wall's header, open the wall-group drop down and pick
    "2 — 192.168.0.20". The entry changes colour from blue to orange — it is now in another videowall
    system. Studio Manager deletes it on the old engine and creates it on the new one.

  4. Build it. In the settings, set Wall group to 2 — 192.168.0.20 and press Create Wall.
    Only that engine is touched; the walls on 192.168.0.10 are untouched.

Group 2: 1 wall confirmed on 192.168.0.20:6100.
  1. Verify. Press Build Room with group 2 selected. The second engine's room carries markers
    only for the walls of group 2 — it never advertises the other system's walls.

image-20260925-085649.png

To work on both systems at once, select all engines in the Wall group drop down. Create Wall
then rebuilds every group on its own engine in one go.


Troubleshooting

Status message

Cause

Fix

No TrackingHub connection.

Studio Manager is not connected to Tracking Hub.

Connect to Tracking Hub first.

No videowall service is in wall group N.

No service carries that group.

Set the Wall Group of a videowall service in the topology, or move the wall to a group that has one.

Videowall service is not running.

The service exists but is stopped.

Activate the service in the topology.

engine at …:6100 is not on air.

The engine is reachable but not on air.

Put the engine on air.

wall group resolves to 2 running engines (expected 1).

Two videowall services share one group — only possible in a hand-edited configuration.

Give each service its own group.

only 1 of 2 walls reached …; missing: Backwall2.

The engine did not create every wall container.

Check the engine log; run Create Wall again.

No wall is in group N.

The selected group has no walls in the editor.

Select the right group, or move a wall into it.

Wall stays black, test room shows nothing

The GFX channel of the walls and of the content differ, or the wall containers do not exist.

Check GFX channel in the settings, then re-run Create Wall (the channel is only applied when the wall is built).


Checklist

  • [ ] One videowall service per engine, active, with a unique wall group

  • [ ] Engine on air

  • [ ] GFX channel chosen, and content played out on that channel

  • [ ] Every wall in the group of the engine that should render it

  • [ ] Create Wall confirmed every wall on its engine

  • [ ] Test room grid continuous across the wall edges

  • [ ] Test room cleared again before going on air