Use the Configuration Panel to save and load Studio configuration profiles, select modes of operation including frequency, and to set some user interface options.
Open: Opens a Tracking Hub configuration file. The name of the currently loaded configuration file is always displayed in the top bar, between the application name and main menu.
New Configuration: Creates a new, empty Studio configuration.
Save: Saves the current Studio configuration.
Save As: Saves the current Studio configuration with a new name.
Reset Configuration: Resets the current Studio configuration. Note that the loaded configuration file is only changed if you click Save after resetting the configuration.
Refresh UI: Reloads the actual configuration. Use this to apply any changes third party software has made to the Tracking Hub parameters, so that the changes can be visualized in the Studio Manager.
Synchronize Backup: Writes the current configuration to the Tracking Hub. This button appears only when a backup rule, Master or Slave, is configured. Close the Lens File Editor first — while it is open, the command is refused with a message.
View Log: Opens or closes the Log Panel.
View Timing Analysis: Opens the Timing Analysis Window.
LensFile Editor: Opens the Lens File Calibration Tool.
Target Detection / Send Target Data: Opens the Target Detection dialog. You are asked to select the rig to work with before the dialog opens. The Lens File Editor is not available while the Target Detection dialog is open.
Note: New Configuration and Reset Configuration are disabled while a camera filter is active. The tool tip of the greyed out button states the reason.
Frequency: Selects the production frequency:
50 Hz,60 Hzor59.94 Hz,29.97Hz,30 Hz,25 Hz,24 Hz.
Synchronization Mode: Selects synchronization mode for the Tracking Hub:
Freerun: Does not synchronize. The Tracking Hub uses its own time base, corresponding with the configured frequency.
AV-Card: Uses an installed Plura card to synchronize.
Viz Engine: Synchronizes with a Viz Engine running on the same computer.
NDI: Please see: Embedded NDI Tracking Data.
Tip: If the selected synchronization mode is followed by a red box with a white horizontal line, this indicates synchronization issues.
Send Delay: Sets the time Tracking Hub waits until it sends tracking data to Viz Engine. This setting is especially important if your tracking delay is less than one field. With the help of the Timing Analysis, the transmission time can be set after the arrival of the tracking data. If your tracking delay is larger than one field, set the send delay value to No Delay. This reduces the CPU usage.
See Also