- 1. Introduction
- 2. Connecting to Viz Engine
- 3. How Commands Are Structured
- 4. Sending Commands and Reading Responses
- 5. Addressing Containers in the Scene Tree
- 6. Getting Started — Your First Commands
- 7. Practical Examples
- Example 1: Complete Lower Third Workflow
- Example 2: Reading and Modifying Transformations
- Example 3: Show/Hide Containers
- Example 4: Changing Colors
- Example 5: Working with Multiple Directors
- Example 6: Taking Snapshots
- Example 7: Monitoring Engine Performance
- Example 8: Shared Memory (Real-Time Data Injection)
- Example 9: Batch Mode (Multiple Commands, One Response)
- Example 10: Flicker-Free Multi-Command Updates
- 8. Working with Multiple Engine Instances
- 9. Error Handling Best Practices
- 10. Quick Reference — Most Useful Commands
- 11. Common Mistakes to Avoid
- 12. Further Reading
1. Introduction
Viz Engine is a real-time graphics rendering engine used in broadcast television. Every control application — whether it's Viz Trio preparing a lower third, Viz Pilot filling a template, a newsroom automation system, or your own custom tool — communicates with Viz Engine by sending text commands over a TCP socket.
This guide teaches you how to connect to Viz Engine, how commands are structured, and how to send and receive them. By the end, you'll be able to load scenes, modify text and graphics, trigger animations, and monitor the engine — all from code.
What You Can Do via Commands
Load and unload scenes on the renderer
Modify text, images, materials, and transformations in a live scene
Start, stop, and control animations (directors)
Read and write shared memory for real-time data injection
Take snapshots of the rendered output
Monitor engine performance (FPS, GPU memory, render time)
Manage the engine lifecycle (restart, shutdown, configuration)
2. Connecting to Viz Engine
The TCP Socket
Viz Engine listens for commands on a TCP socket. The connection parameters are:
Parameter | Value |
Protocol | Raw TCP (no TLS, no HTTP framing) |
Default Port | 6100 |
Encoding | Plain ASCII text |
Message Separator / Terminator | Null character (\0) |
Max Connections | 255 simultaneous (configurable) |
How to Connect
Open a TCP socket to the engine's hostname or IP address on port 6100. Once connected, you can immediately start sending commands.
Command Syntax
CMD_ID BLANK_CHARACTER CMD NULL_BYTE[…]
The CMD_ID is used to identify the command and uses the same ID for the answer, except when the CMD_ID is -1, where no answer is sent back. It is a string and may be composed of a short text and some number, or -1 to instruct the engine not to send an answer.
General Example
MYID123 MAIN VERSION\0
will send back this answer
MYID123 Version: 5.5.2.40039
Python example:
import socket# Connect to Viz Enginesock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)sock.connect(("viz-engine-host", 6100))# Send a command (must end with \0)sock.sendall(b"MYID123 MAIN VERSION\0")# Read the response (also newline-terminated)response = sock.recv(4096).decode("ascii").strip()print(f"Engine version: {response}")sock.close()PowerShell example:
first, we create a small helper function to read until we receive the null byte:
function Read-UntilNul { param( [Parameter(Mandatory)] [System.IO.Stream]$Stream, [System.Text.Encoding]$Encoding = [System.Text.Encoding]::UTF8, [int]$MaxBytes = 1048576 ) $bytes = New-Object System.Collections.Generic.List[byte] while ($true) { $b = $Stream.ReadByte() if ($b -lt 0) { throw "Connection closed before NUL terminator was received." } if ($b -eq 0) { break } $bytes.Add([byte]$b) if ($bytes.Count -ge $MaxBytes) { throw "Message exceeded MaxBytes ($MaxBytes) without NUL terminator." } } return $Encoding.GetString($bytes.ToArray())}Then we can use the following snippet
$client = New-Object System.Net.Sockets.TcpClient("localhost", 6100)$stream = $client.GetStream()$utf8NoBom = [System.Text.UTF8Encoding]::new($false)$writer = New-Object System.IO.StreamWriter($stream, $utf8NoBom, 1024, $true)$reader = New-Object System.IO.StreamReader($stream, [System.Text.Encoding]::UTF8, $false, 1024, $true )# Send command$writer.Write("MYID789 MAIN VERSION" + [char]0)$writer.Flush()$response = Read-UntilNul -Stream $stream -Encoding ([System.Text.Encoding]::UTF8)Write-Host "Engine version: $response"$writer.Dispose()$stream.Dispose()$client.Close()$client.Dispose()This would produce e.g
Engine version: MYID789 Version: 5.5.2.40039
C# example:
using System;using System.Net.Sockets;using System.Text;class Program{ static void Main(string[] args) { string host = args.Length > 0 ? args[0] : "viz-engine-host"; int port = 6100; Console.WriteLine($"Connecting to {host}:{port}..."); try { using var client = new TcpClient(host, port); client.ReceiveTimeout = 5000; var stream = client.GetStream(); Console.WriteLine("Connected. Sending command..."); // Send command immediately — VizEngine expects null-terminated commands byte[] cmd = Encoding.ASCII.GetBytes("MYID456 MAIN VERSION\0"); stream.Write(cmd, 0, cmd.Length); // Read all responses until nothing more arrives while (true) { string response = ReadNullTerminated(stream); if (response.Length == 0) break; Console.WriteLine($"Response: {response}"); // Stop after our tagged response if (response.StartsWith("MYID456")) break; } } catch (SocketException ex) { Console.WriteLine($"Connection failed: {ex.Message}"); } catch (Exception ex) { Console.WriteLine($"Error: {ex.Message}"); } } static string ReadNullTerminated(NetworkStream stream) { var buffer = new System.Collections.Generic.List<byte>(256); int b; while ((b = stream.ReadByte()) > 0) // 0 = null terminator, -1 = closed buffer.Add((byte)b); return Encoding.ASCII.GetString(buffer.ToArray()); }} Important Connection Rules
Always terminate commands with a null byte (\0). Without it, the engine buffers the input and never processes the command.
Keep connections open for the duration of your session. Opening and closing connections for every command adds latency and wastes connection slots.
Close connections when done. The engine has a maximum of 255 simultaneous connections. Leaked connections eventually block all clients.
One response per command. Every command you send produces exactly one response line. Read one line after each send.
3. How Commands Are Structured
The Command Format
Every command follows this pattern: OBJECT*PATH*PROPERTY VERB [arguments]
There are three parts separated by spaces:
Part | What it does | Example |
Object Path | Identifies what you're targeting | MAIN_SCENE*TREE*$Title*GEOM*TEXT |
Verb | Identifies what operation to perform | SET, GET, INVOKE |
Arguments | The data for the operation (optional) | "Hello World" |
The Asterisk Delimiter
The object path uses asterisks (*) as delimiters to navigate through a hierarchy of objects. Think of it like a file path, but with * instead of /.
MAIN_SCENE * TREE * $Title * TRANSFORMATION * POSITION * X │ │ │ │ │ │ │ │ │ │ │ └─ The X coordinate │ │ │ │ └─ Position property │ │ │ └─ Transformation of the container │ │ └─ Container named "Title" ($ = by name) │ └─ The scene tree (hierarchy of containers) └─ The currently loaded main scene Always Use Asterisks: The path delimiter is always *. Do not use dots (.) or slashes (/) — these will not work and will return an error
Common Verbs
Verb | Purpose | Example |
GET | Read the current value of a property | *POSITION*X GET |
SET | Write a new value to a property | *POSITION*X SET 200.0 |
INVOKE | Execute an action or trigger a function | *FUNCTION*Toggle*switch INVOKE |
SET_OBJECT | Load or assign a scene/object | RENDERER SET_OBJECT SCENE*path |
START | Start an animation | RENDERER*STAGE START DEFAULT |
CONTINUE | Continue a paused animation | *DIRECTOR*name CONTINUE |
SHOW | Run a director to its end | *DIRECTOR*name SHOW |
ADD | Add a child element | MAIN_SCENE*TREE ADD TOP |
DELETE | Remove an element | MAIN_SCENE*TREE*$old DELETE |
Top-Level Objects
Commands always start with one of these top-level objects:
Object | What it represents |
RENDERER | The active renderer — load scenes, take snapshots, control layers |
MAIN_SCENE | The currently loaded scene — its tree, stage, shared memory |
SCENE | The scene pool — load, check, save, close scenes in memory |
MAIN | Engine-level controls — version, restart, shutdown |
VIZ_COMMUNICATION | Distributed shared memory (cross-engine data) |
GLOBAL | System-wide shared memory (local to this engine) |
CONFIGURATION | Runtime configuration read/write |
DATABASE | Graphic Hub connection management |
4. Sending Commands and Reading Responses
The Request-Response Cycle
Communication is synchronous — you send one command, and the engine sends back one response. The response is always a single line of text terminated by a newline.
You send: VERSION\n Engine replies: 5.5.0.12345\n You send: MAIN_SCENE*TREE*$Title*GEOM*TEXT GET\n Engine replies: Breaking News\n You send: MAIN_SCENE*TREE*$Title*GEOM*TEXT SET "Hello World"\n Engine replies: \n (empty = success, no value to return)
Response Types
Situation | What the response looks like |
GET with a value | The value as a text string, e.g. "150.0" |
SET success | Empty response (just a newline) |
Error | A string containing the word ERROR, e.g. "ERROR: Unknown container" |
Error Detection
Viz Engine does not return numeric error codes or JSON. To detect an error, check whether the response contains the substring `ERROR`:
def send_command(sock, command): sock.sendall((command + "\n").encode("ascii")) response = sock.recv(4096).decode("ascii").strip() if "ERROR" in response: raise RuntimeError(f"Viz Engine error: {response}") return response Liveness Check
To verify the engine is alive and accepting commands, send: IS_RENDERER_READY
If you receive a 1, the engine is responsive. If the call times out, the engine is unresponsive or unreachable.
5. Addressing Containers in the Scene Tree
A Viz Engine scene is a tree of containers. Each container can hold geometry, text, images, plugins, and transformations. To target a container in a command, you navigate the tree using the MAIN_SCENE*TREE prefix.
Three Ways to Address a Container
Prefix | Method | Example | When to use |
$ | By name | MAIN_SCENE*TREE*$Title | Most common — uses the container's name |
# | By object ID | MAIN_SCENE*TREE*#1234 | When you know the numeric ID |
/ | By index (1-based) | MAIN_SCENE*TREE*/1/2/3 | When addressing by tree position |
Navigating Nested Containers
Containers can be nested. Chain the names to reach deep into the tree: MAIN_SCENE*TREE*$root*$child*$grandchild
This addresses the container named "grandchild" which is a child of "child", which is a child of "root".
Accessing Properties on a Container
Once you've addressed a container, append the property you want to access:
MAIN_SCENE*TREE*$Title*TRANSFORMATION*POSITION*X GET MAIN_SCENE*TREE*$Title*GEOM*TEXT SET "Breaking News" MAIN_SCENE*TREE*$Title*MATERIAL*DIFFUSE_COLOR SET 1.0 0.0 0.0 1.0 MAIN_SCENE*TREE*$Logo*ACTIVE SET 1Key Container Properties
Property Path | What it controls |
*TRANSFORMATION*POSITION*X/Y/Z | 3D position |
*TRANSFORMATION*ROTATION*X/Y/Z | 3D rotation (degrees) |
*TRANSFORMATION*SCALING | Scale (can set X Y Z as a triple) |
*GEOM*TEXT | Text content (on text geometry) |
*MATERIAL*DIFFUSE_COLOR | Material color (R G B A, each 0.0–1.0) (Classic Pipeline) |
*MATERIAL*ALPHA | Material transparency (0.0–1.0) (Classic Pipeline) |
*ACTIVE | Visibility (1 = visible, 0 = hidden) |
*TEXTURE*IMAGE | Assigned texture/image (Classic Pipeline) |
*FUNCTION*PluginName*param | Plugin parameter |
*SCRIPT*INSTANCE*VarName | VizScript variable |
6. Getting Started — Your First Commands
Here is a step-by-step sequence to get you started. Each command is shown with what it does and what response to expect.
Step 1: Check That the Engine Is Ready
VERSION → "5.5.0.12345" IS_RENDERER_READY → "1" (1 = ready, 0 = not ready)
Always Check Readiness: IS_RENDERER_READY should return "1" before you send any scene or rendering commands. After engine startup or a scene load, the renderer may need a moment to initialize.
Step 2: Load a Scene
RENDERER SET_OBJECT SCENE*Scenes/MyLowerThird → "" (empty = success) This loads the scene located at Scenes/MyLowerThird in the Graphic Hub database and puts it "on air" on the main renderer layer.
Step 3: Modify Scene Content
MAIN_SCENE*TREE*$Headline*GEOM*TEXT SET "Breaking News" → "" MAIN_SCENE*TREE*$Subline*GEOM*TEXT SET "Live from the studio" → "" Step 4: Trigger an Animation
RENDERER*STAGE*DIRECTOR*Main START → "" This starts the director named "Main" in the scene's stage, which typically animates the lower third in.
Step 5: Read Back Values
MAIN_SCENE*TREE*$Headline*GEOM*TEXT GET → "Breaking News" MAIN_SCENE*TREE*$Headline*TRANSFORMATION*POSITION*X GET → "0.0" RENDERER*STAGE*DIRECTOR*Main*STATE GET → "STOPPED" (animation finished) Step 6: Animate Out and Unload
RENDERER*STAGE*DIRECTOR*Main CONTINUE REVERSE → "" RENDERER SET_OBJECT → "" (empty argument = unload current scene) 7. Practical Examples
Example 1: Complete Lower Third Workflow
This is the most common broadcast workflow — load a template, fill it with data, animate it in, update it, then animate it out.
-- 1. Load the template RENDERER SET_OBJECT SCENE*Templates/LowerThird -- 2. Fill text fields MAIN_SCENE*TREE*$Name*FUNCTION*ControlText*input SET "John Smith" MAIN_SCENE*TREE*$Title*FUNCTION*ControlText*input SET "Senior Correspondent" -- 3. Animate in RENDERER*STAGE*DIRECTOR*Main START -- 4. (Wait for on-air duration...) -- 5. Update text while on air MAIN_SCENE*TREE*$Title*FUNCTION*ControlText*input SET "Live from London" -- 6. Animate out RENDERER*STAGE*DIRECTOR*Main SHOW Example 2: Reading and Modifying Transformations
-- Read current position MAIN_SCENE*TREE*$Logo*TRANSFORMATION*POSITION*X GET → "100.0" MAIN_SCENE*TREE*$Logo*TRANSFORMATION*POSITION*Y GET → "50.0" -- Move the logo MAIN_SCENE*TREE*$Logo*TRANSFORMATION*POSITION*X SET -200.0 MAIN_SCENE*TREE*$Logo*TRANSFORMATION*POSITION*Y SET 300.0 -- Rotate 45 degrees around Z axis MAIN_SCENE*TREE*$Logo*TRANSFORMATION*ROTATION*Z SET 45.0 -- Scale to double size MAIN_SCENE*TREE*$Logo*TRANSFORMATION*SCALING SET 2.0 2.0 2.0 Example 3: Show/Hide Containers
-- Hide a container (and all its children) MAIN_SCENE*TREE*$SponsorLogo*ACTIVE SET 0 -- Show it again MAIN_SCENE*TREE*$SponsorLogo*ACTIVE SET 1 Example 4: Changing Colors
-- Set material to red (R=1, G=0, B=0, A=1) MAIN_SCENE*TREE*$Bar*MATERIAL*DIFFUSE_COLOR SET 1.0 0.0 0.0 1.0 -- Make it semi-transparent MAIN_SCENE*TREE*$Bar*MATERIAL*ALPHA SET 0.5 Example 5: Working with Multiple Directors
Scenes often have multiple directors for different animation segments:
-- Check director state RENDERER*STAGE*DIRECTOR*InAnimation*STATE GET → "STOPPED" -- Start the "in" animation RENDERER*STAGE*DIRECTOR*InAnimation START -- Later, start the "out" animation RENDERER*STAGE*DIRECTOR*OutAnimation START -- Or use SHOW to jump to the end instantly RENDERER*STAGE*DIRECTOR*InAnimation SHOW Example 6: Taking Snapshots
-- Capture the current render to a file RENDERER SNAPSHOT "C:\Snapshots\frame001.png" RGBA 1920 1080 Example 7: Monitoring Engine Performance
RENDERER*CURRENT_FPS GET → "50.0" RENDERER*RENDER_TIME GET → "4.2" (milliseconds per frame) MAIN*GPU_MEMORY GET → "2048" (MB) MAIN*RAM_USAGE GET → "4096" (MB) Example 8: Shared Memory (Real-Time Data Injection)
Shared memory lets external systems inject data that running scenes can pick up automatically:
-- Set a shared memory value (via command interface) VIZ_COMMUNICATION*MAP SET_ELEMENT "score_home" "3" VIZ_COMMUNICATION*MAP SET_ELEMENT "score_away" "1" -- Read back VIZ_COMMUNICATION*MAP GET_ELEMENT "score_home" → "3" -- Clear all shared memory VIZ_COMMUNICATION*MAP CLEAR
High-Volume Data: For high-frequency data updates (for example, live sports telemetry), use the dedicated SHM TCP port (3001) or SHM UDP port (3000) instead of the command interface. Commands sent via port 6100 block the render queue and can cause frame drops.
Example 9: Batch Mode (Multiple Commands, One Response)
When you need to execute several commands atomically:
MYID BATCH START -1 MAIN_SCENE*TREE*$Score_Home*GEOM*TEXT SET "3" -1 MAIN_SCENE*TREE*$Score_Away*GEOM*TEXT SET "1" -1 MAIN_SCENE*TREE*$Timer*GEOM*TEXT SET "87:32" -1 BATCH STOP → "" (single response for the entire batch with MYID as answer ID)All commands inside BATCH BEGIN / BATCH END execute sequentially in the engine, but you only receive one response at the end. This reduces network round-trips and ensures all updates appear in the same frame. It is important to send the consecutive lines after BATCH START with an ID of -1.
Example 10: Flicker-Free Multi-Command Updates
To update multiple properties without the audience seeing intermediate states:
-- Pause rendering updates RENDERER*UPDATE SET 0 -- Make all your changes MAIN_SCENE*TREE*$Name*GEOM*TEXT SET "Jane Doe" MAIN_SCENE*TREE*$Title*GEOM*TEXT SET "Weather Presenter" MAIN_SCENE*TREE*$Photo*TEXTURE*IMAGE SET IMAGE*Photos/jane -- Resume rendering — all changes appear in one frame RENDERER*UPDATE SET 1 8. Working with Multiple Engine Instances
When multiple Viz Engine instances run on the same machine, each instance offsets its ports: Port = Base Port + (Instance Number - 1)
Instance | Command Port | REST Port | Start Command |
1 (default) | 6100 | 61000 | viz.exe -u1 |
2 | 6101 | 61001 | viz.exe -u2 |
3 | 6102 | 61002 | viz.exe -u3 |
To target instance 3, connect to port 6102 instead of 6100.
9. Error Handling Best Practices
Always Check for ERROR in Responses
response = send_command("MAIN_SCENE*TREE*$NonExistent*POSITION GET") # response might be: "ERROR: Unknown container"The Engine Will Not Crash on Bad Input
Viz Engine is designed to handle invalid commands gracefully:
What you send | What happens |
Wrong argument type | Silently ignored or returns ERROR |
Missing required arguments | Returns ERROR message |
Extra arguments | Extra arguments are ignored |
Invalid object path | Returns "Unknown container" error |
Out-of-range number | Clamped to valid range |
Empty command | Returns empty or ERROR |
Always Gate on Renderer Readiness
After engine startup or loading a scene, always wait for the renderer to be ready:
while True: response = send_command("MAIN IS_RENDERER_READY") if response == "1": break time.sleep(0.1) Clean Up After Yourself
-- Close the scene from memory SCENE*Scenes/MyLowerThird CLOSE -- Release GPU resources (textures, geometry) POOLS CLEANUP Without POOLS CLEANUP, textures and geometry from unloaded scenes remain in GPU memory.
10. Quick Reference — Most Useful Commands
Engine Status
Command | Returns |
MAIN VERSION | Engine version string |
MAIN IS_RENDERER_READY | "1" if ready, "0" if not |
MAIN IS_ON_AIR GET | "1" if on air |
RENDERER*CURRENT_FPS GET | Current FPS |
Scene Loading
Command | What it does |
RENDERER SET_OBJECT SCENE*path | Load scene on air |
RENDERER SET_OBJECT | Unload current scene |
SCENE*path EXIST | Check if scene exists in database |
SCENE*path LOAD | Pre-load into memory (not on air) |
SCENE*path CLOSE | Release from memory |
Scene Content
Command | What it does |
MAIN_SCENE*TREE*$name*GEOM*TEXT SET "text" | Set text content |
MAIN_SCENE*TREE*$name*GEOM*TEXT GET | Read text content |
MAIN_SCENE*TREE*$name*ACTIVE SET 0/1 | Hide/show container |
MAIN_SCENE*TREE*$name*TRANSFORMATION*POSITION*X SET val | Set position |
MAIN_SCENE*TREE*$name*MATERIAL*DIFFUSE_COLOR SET R G B A | Set color |
Animations
Command | What it does |
RENDERER*STAGE START DEFAULT | Start default director |
RENDERER*STAGE*DIRECTOR*name START | Start named director |
RENDERER*STAGE*DIRECTOR*name SHOW | Jump to director end |
RENDERER*STAGE*DIRECTOR*name CONTINUE | Resume paused director |
RENDERER*STAGE*DIRECTOR*name*STATE GET | Get state: RUNNING, STOPPED, PAUSED |
Plugin Parameters
Command | What it does |
*FUNCTION*ControlText*input SET "text" | Set ControlText value |
*FUNCTION*ControlImage*source SET "IMAGE*path" | Set ControlImage |
*FUNCTION*Toggle*switch INVOKE | Toggle visibility |
*FUNCTION*PluginName*param GET | Read any plugin param |
Shared Memory
Command | What it does |
VIZ_COMMUNICATION*MAP SET_ELEMENT "key" "val" | Set distributed SHM |
VIZ_COMMUNICATION*MAP GET_ELEMENT "key" | Read distributed SHM |
MAIN_SCENE*MAP SET_ELEMENT "key" "val" | Set scene-local SHM |
GLOBAL*MAP SET_ELEMENT "key" "val" | Set system-wide SHM |
Cleanup
Command | What it does |
POOLS CLEANUP | Release all unused resources |
POOLS*TEXTURE CLEANUP | Release unused textures only |
11. Common Mistakes to Avoid
Mistake | Correct Approach |
Using dots as delimiter: MAIN_SCENE.TREE.$Title | Use asterisks: MAIN_SCENE*TREE*$Title |
Forgetting the $ prefix: MAIN_SCENE*TREE*Title | Always prefix names: MAIN_SCENE*TREE*$Title |
Forgetting the newline at end of command | Every command must end with \n |
Connecting to port 6100 for instance 3 | Use port 6102 (6100 + 3 - 1) |
Not closing TCP connections | Always close — 255 max; leaks block everyone |
Expecting JSON error responses | Check for ERROR substring in plain text |
Not calling POOLS CLEANUP after unloading scenes | GPU memory accumulates without cleanup |
Not checking IS_RENDERER_READY | Always wait for readiness after startup/load |
Sending high-volume data via port 6100 | Use SHM ports (3001 TCP / 3000 UDP) instead |
12. Further Reading
Commands.xml self-documentation: Run viz.exe --doc to generate a complete XML file of every available command with argument types and ranges. Output: C:\ProgramData\vizrt\VizEngine\commands.xml
REST API: Viz Engine also exposes an HTTP API on port 61000 for stateless control.
WebSocket: A WebSocket interface is available on port 6900 for bidirectional web-based control.
Shared Memory ports: For high-frequency data, connect to TCP port 3001 (reliable) or UDP port 3000 (fast, unreliable) using the pipe-delimited format: key|value\0